Posttensioned Slab-on-Grade.
The most common uses of posttensioned slab-on-grade are to resist expansive soil forces or when the projected differential settlement exceeds the tolerable value for a conventional (lightly reinforced) slab-on-grade. For example, posttensioned slabs-on-grade are frequently recommended if the projected differential settlement is expected to exceed 0.75 in. (2 cm).
The Post-Tensioning Institute (1996) has prepared installation and field inspection procedures for posttensioned slab-on-grade. Posttensioned slab-on-grade consists of concrete with embedded steel tendons that are encased in thick plastic sheaths. The plastic sheath prevents the tendon from coming in contact with the concrete and permits the tendon to slide within the hardened concrete during the tensioning operations. Usually tendons have a dead end (anchoring plate) in the perimeter (edge) beam and a stressing end at the opposite perimeter beam to enable the tendons to be stressed from one end. However, it is often recommend that the tendons in excess of 100 ft (30 m) be stressed from both ends. For typical anchorage details for the tendons, see the Post-Tensioning Institute (1996).
Because posttensioned slab-on-grade perform better (i.e., less shrinkage related concrete cracking) than conventional slab-on-grade, they are more popular even for situations where low levels of settlement are expected. Posttensioned slab-on-grade has become common for situations where it is desirable to limit the amount and width of concrete shrinkage cracks.